printPrint this page

Hurricane Resistant - HIS1400 Series Fixed Offset

Fixed Window

Frame Depth (inches) 4.0

Description Fixed offset window for hurricane-impact resistance.

 

  • Applications
  • Hurricane Resistant

Test Size (inches)

48 x 83-1/2 / 60 x 106 / 78 x 106

Water Resistance (psf)

12

Design Pressure Positive (psf)

50/80/35

Design Pressure Negative (psf)

80/80/60

Large Missle

Meets

Small Missle

Meets

Notes

The water resistance performance values provided above were achieved in a controlled lab environment. Performance of our products in the field will vary depending on product configurations, installation methods, and ambient conditions. AAMA 502 “Voluntary Specification for Field Testing of Newly Installed Fenestration Products” should be adhered to for testing installed products.

Standard Features

  • Fixed windows for hurricane-impact resistance
  • Offset lites simulate the appearance of a hung window
  • Provides large missile impact protection
  • Offers passive protection from wind-borne debris without shutters
  • Thermally broken frame with IG option for superior energy savings
  • Bead glazing up to 1” thick
  • Putty bead frame style with historic grids
  • Coped corner construction
  • Mulls to fixed and operable products of same frame depth

Optional Features

  • Dual windows combine two frames joined by thermal barrier; each frame may be single or dual glazed
  • Dual-glazed split sash to permit use of high performance glazing combinations & integral blinds
  • True and exterior-applied muntin grids
  • Historic grids and grids at interior glass
  • Sloped glazing leg option
  • Thermal strut (S1400H) version available
  • Offset simulated hung (S1400H) available
  • Dual finish (two-tone color) option (S1400H)
  • Blast-resistant (B1400)

Technical Data

Installation Accessories

4" Frame Accessories
View Accessories >

CAD Files

Description

AutoCAD

PDF

Fixed Offset; Annealed-Lami IG; Large Missile
Fixed Offset; Annealed-Lami IG; Small Missile
Fixed Offset; Annealed-Lami IG; Large Missile
Fixed Offset; Annealed-Lami IG; Small Missile
Fixed Offset; Tempered-Lami IG; Large Missile
Fixed Offset; Annealed-Lami IG; Small Missile

TESTING:ASTM E1886, ASTM E1996, and/or TAS 201, TAS 202, TAS 203