Commercial

The commercial window and door products includes all products except hurricane-resistant and blast-resistant products. For those products click on the appropriate category header.

printPrint this page

Commercial

| Casement Window | Doors | Dual Action Window | Fixed Window | Horizontal Sliding Window | Hung Window | Projected Window | Window Wall
Top

Name
Frame Depth
AAMA Rating
Air Infiltration (cfm/ft2)
Water Resistance (psf)
Design Pressure Positive (psf)
U-Value
CRF
STC
4 Inch
AW-PG110
<0.01
12
110
0.31 - 0.37
65
Top

Casement Window

Name
Frame Depth
AAMA Rating
Air Infiltration (cfm/ft2)
Water Resistance (psf)
Design Pressure Positive (psf)
U-Value
CRF
STC
2.5
AW-PG100
<0.10
12
100
0.44-0.52
51-59
3.0
AW-PG100
<0.10
12
100
0.38 - 0.43
65
3.375
AW-PG100
<0.10
12
100
0.25-0.37
66-72
3.25
CW-PG90
0.03
12.11
90.23
0.42 - 0.50
3.375
AW-PG85
0.08
12.11
±85.21
0.34-0.41
71
Top

Doors

Name
Frame Depth
AAMA Rating
Air Infiltration (cfm/ft2)
Water Resistance (psf)
Design Pressure Positive (psf)
U-Value
CRF
STC
4.0
AW-PG80
0.13
12
80.20
0.39 - 0.59
48
2.75 - 3.375
AW-PG50 / AW-PG40 (low sill)
0.05
12.11

(Low Sill: Limited Water, Contact Graham)

60.15/90.23
0.29-0.42
N/A
N/A
Top

Dual Action Window

Name
Frame Depth
AAMA Rating
Air Infiltration (cfm/ft2)
Water Resistance (psf)
Design Pressure Positive (psf)
U-Value
CRF
STC
3.375
CW-PG70
<0.10
12
70
0.20-0.37
66-72
Top

Fixed Window

Name
Frame Depth
AAMA Rating
Air Infiltration (cfm/ft2)
Water Resistance (psf)
Design Pressure Positive (psf)
U-Value
CRF
STC
3.25
AW-PG120
0.01
12.11
120.30
0.35 - 0.57
63
31 - 36
3.25
AW-PG70
0.01
12
70
0.37 - 0.46
54
2.5
AW-PG100
<0.10
12
100
0.28-0.40
57-62
4.0
AW-PG85
<0.01
15
85.21
0.27 - 0.37
75
4.5
AW-PG80
<0.01
15
80
0.28 - 0.33
75
3.0
AW-PG100
<0.10
12
100
0.31 - 0.39
66
39
3.375
AW-PG100
<0.10
12
100
0.25-0.37
66-72
4.0
AW-PG115
0.03
15.04
120.30
0.30-0.42
66
3.25
AW-PG110
0.01
12.11
110.28
0.28 - 0.37
3.375
AW-PG100
<0.01
15.04
±100.25
0.26-0.34
78
Top

Horizontal Sliding Window

Name
Frame Depth
AAMA Rating
Air Infiltration (cfm/ft2)
Water Resistance (psf)
Design Pressure Positive (psf)
U-Value
CRF
STC
3.25
AW-PG40 (XO) / AW-PG55 D.S. (XOX) / AW-PG55 D.S. (XO)
0.19
11.07
40.10/55.14
0.44 - 0.62
58
33-38
4.0
AW-PG60
0.12
12.11
60.15
0.32 - 0.45
65
N/A
Top

Hung Window

Name
Frame Depth
AAMA Rating
Air Infiltration (cfm/ft2)
Water Resistance (psf)
Design Pressure Positive (psf)
U-Value
CRF
STC
3.25
0.20
10.03
45.11
0.40 - 0.61
55
32-37
4.0
AW PG55: AW-PG90
0.26
12
55/90
0.36–0.41 (Historic Profile) 0.30–0.35 (Flat Profile)
64
N/A
4.0
AW-PG50: AW-PG70
0.18
12.11
50.13 / 70.18
0.35 - 0.44
60
4.5
AW-PG60
0.27
12
60.15
0.38 - 0.40
60
35
3.25
AW-PG75 / AW-PG50
0.13
12.11
75.19/50.13
0.43 - 0.51
50
Top

Projected Window

Name
Frame Depth
AAMA Rating
Air Infiltration (cfm/ft2)
Water Resistance (psf)
Design Pressure Positive (psf)
U-Value
CRF
STC
2.5
AW-PG100
<0.10
12
100
0.44-0.52
51-59
3.0
AW-PG100
<0.10
12
100
0.39 - 0.46
N/A
3.375
AW-PG100
<0.10
12
100
0.25-0.43
66-72
3.25
CW-PG100: CW-PG40 (Fixed w/ Floating Vent 93 x 98)
0.01
12.11
100.25
0.43 - 0.51 | 0.37-0.44 (Fixed w/ Floating Vent)
Top

Window Wall

Name
Frame Depth
AAMA Rating
Air Infiltration (cfm/ft2)
Water Resistance (psf)
Design Pressure Positive (psf)
U-Value
CRF
STC
4.5
0.10
12
30.8
0.19 - 0.37 (Fixed) 0.30 - 0.43 (IS Casement) 0.37 - 0.51 (PO Awning)
72 (fixed); 70 (operable)
37-38